We install, replace and repair backflow assemblies as licensed plumbers. We do not hold the certificate that lets anyone sign off your annual test, so give us the address and we will tell you whose job it is.

Backflow preventer assembly installed on a copper water line with its test tag

A backflow preventer is a one-way gate on a water line. Pressure normally pushes water toward the building. Drop that pressure, with a main break down the street or a hydrant opened hard, and the flow reverses, pulling whatever sat at the far end of a hose or an irrigation line back toward the drinking water. The Virginia Residential Code says it in one sentence at Section P2902.1: a water system must be built so nonpotable liquids, solids or gases cannot get into the potable supply.

That matters more than people assume, because the water arriving at your meter is being actively managed. Every public system here carries chloramine as its year-round disinfectant residual, and the utilities dose orthophosphate to hold a protective film inside the pipe. Loudoun Water publishes its target as a minimum of 0.90 ppm orthophosphate with pH at 7.0 or above. Your assembly stops your property pushing something back into that.

Start With The Part Most Companies Leave Out

We cannot perform your annual certification test. Virginia certifies Backflow Prevention Device Workers under Code of Virginia § 54.1-1129, and § 54.1-1128 defines the role as the maintenance, repair, testing and periodic inspection of cross connection control devices. Nobody here holds it, and we do not appear on Fairfax County's Authorized Vendor List. So when a test is due, the test is not ours to do.

Here is the wrinkle, and it is why so many websites get this wrong. The state certificate is voluntary. The statute says so outright, and it also says a locality has to accept it as proof of training. The binding requirement does not come from Richmond. It comes from whichever water authority serves your address, and those authorities do not agree with one another.

Six Water Authorities, Six Different Answers

None of the below is our policy. Each line is somebody else's published program, and together they explain why a company that tests happily in one county is shut out of the next.

Who runs cross connection control, by address
WhereWhose programWhat it requires
Woodbridge, Dale City, Lake Ridge, the rest of Prince WilliamPrince William WaterTestable assemblies tested at installation or repair and annually after that, by a certified backflow testing company. The owner submits the results to the utility's Cross Connection Coordinator. No separate local registration is published.
Fairfax CountyFairfax County cross connectionsThe tester must hold the DPOR Backflow Prevention Device Worker certificate and appear on the county's Authorized Vendor List. We are not on that list. Installing or replacing a device needs a plumbing permit even like for like; the annual test does not.
Sterling, AshburnLoudoun WaterA device is required on every fire suppression and irrigation system, tested at installation and annually after. A failed device has to be repaired or replaced and retested within thirty days of notification, at the customer's expense. Since January 2023 testers must hold a Virginia DPOR tradesman certification.
ArlingtonArlington CountyThe county inspects restaurants and commercial buildings annually for cross connection compliance, and wants devices tested by a Virginia-licensed backflow device professional before that inspection is scheduled. Residential irrigation is inspected after installation, after which third-party inspectors are allowed.
AlexandriaVirginia American WaterThe customer carries installation, permits, annual testing and repair. Testable devices are tested annually and reported through BSI Online. Non-testable residential dual checks are inspected, repaired or replaced on a five-year cycle.
City of ManassasCity of Manassas utilityStricter than its neighbours. The DPOR certificate plus separate registration with the City, carrying a City-issued Backflow Worker card. Annual testing as a minimum, and also on installation, replacement or repair, with a five-year overhaul or replacement cycle that varies by device type. The program document is dated 2016, so confirm the current detail with the City.

What Is Actually Ours

  1. New installationSizing it, placing it where it can be reached, running the pipe and pulling the permit. USBC Section 108.1 makes work on the water supply and distribution system permit work, so there is no grey area here.
  2. ReplacementA condemned device, or one that split over the winter, comes out and a new one goes in. On an older service the tie-in is the interesting part, because what the existing pipe is made of decides how it gets joined. See pipe materials by decade.
  3. Repair and rebuildRelief valves, check springs and seals are serviceable parts, so a failed test is often a rebuild rather than a new assembly. The common kits ride on the truck, which usually means one visit instead of two.
  4. Freeze damageIrrigation assemblies sit above grade by design, which is why they split. If yours was not drained before the first hard freeze, assume damage until somebody opens it up. See frozen and burst pipe work.
  5. Fixing an assembly nobody can reachIf the tester cannot reach the device, you pay for a trip that produced no test. Moving it is plumbing, and plumbing is ours.

The Height Rule Nobody Mentions Until The Tester Arrives

Virginia amended the model code here, and the amendment carries hard numbers. 13VAC5-63-210 rewrites Section P2902.6 to require access for inspection, testing, service, repair, and replacement of a backflow prevention assembly, and to set its mounting height between 12 inches and 60 inches from grade, floor level or service platform. Where the manufacturer's listed height conflicts with that range, the manufacturer's height governs.

It reads like trivia until a tester declines the job. An assembly wedged into a crawl space corner, or boxed in behind a soffit, is not practically testable and is not compliant either. It happens where somebody fitted the device wherever the pipe happened to run. Relocating it is a morning's work and the problem is gone for good.

Fitting One Changes The Rest Of The House

This is the consequence we get asked about least and the one that causes the most trouble later. Put a backflow preventer or a check valve on the service and the plumbing behind it becomes a closed system. Heat water in a closed system and it expands with nowhere to go, so pressure climbs. Virginia Residential Code Section P2903.4 requires a means of controlling that pressure where such a valve sits alongside storage water heating equipment. Note the wording: a means, not a tank. An expansion tank is just the usual answer. The static ceiling in that chapter is 80 psi, and above it a pressure-reducing valve is required at the water service connection.

So a new assembly can legitimately turn into a second line item on your water heater, and that is not an upsell. If somebody quotes you a backflow preventer and says nothing at all about thermal expansion, ask them why.

Where These Devices Hide

  • Every outside hose bibb and wall hydrant. Section P2902.4.3 requires vacuum breaker protection on sillcocks, hose bibbs and wall hydrants. The little brass cap on the spout is it.
  • The irrigation system. Section P2902.5.3 allows an atmospheric vacuum breaker, a pressure vacuum-breaker assembly or a reduced pressure principle assembly. Where chemicals go in, fertilizer included, reduced pressure principle protection is mandatory.
  • The fire sprinkler riser. Worth flagging: the Virginia plumbing classification excludes fire sprinkler contracting except for sprinklers tied into the domestic water supply, so a device on a dedicated fire line can need a sprinkler contractor, not a plumber.
  • A boiler or hydronic fill line. Anywhere treated loop water could push back toward the potable side.
  • A well and a public connection on one property. The textbook cross connection.
  • Commercial kitchens and most commercial buildings. Usually several devices, often on equipment as well as the incoming supply.

One Thing That Gets Confused With All Of This

Alexandria runs a grant paying half the cost of installing a backflow preventer, capped at $2,000, for homes that have had a basement backup after heavy rain. Good program, and nothing to do with anything above it on this page. That device is a sewer backwater valve, which stops sewage coming back up a floor drain, and it lives on the sewer side of the house. The shared word causes real confusion, so we put the difference in writing.

Our Licence, And What It Does Not Cover

1 Stop holds Virginia Class A contractor licence #2705131990 with the plumbing (PLB), HVAC (HVA) and gas fitting (GFC) classifications, verifiable through DPOR. Two things worth knowing. Class A is a dollar threshold, not a quality grade: § 54.1-1100 defines it as $150,000 or more on a single contract, or $1 million in any twelve-month period. And the plumbing classification at 18VAC50-22-20 names backflow prevention devices outright, which is why installation and repair sit squarely with us.

A firm cannot hold that plumbing classification unless a master plumber tradesman stands behind the licence. That is 18VAC50-22-61, and it says more than most of what gets printed on a van. What it is not is a backflow tester certificate. Different statute, different document, and we will not blur the two to win a job.

Common Questions

Can 1 Stop perform my annual backflow test?
No. Nobody here holds the DPOR Backflow Prevention Device Worker certificate and we are not on Fairfax County's Authorized Vendor List, so the annual certification test is not work we can carry out. Installation, replacement and repair of the assembly are, and so is the permit that goes with them.
Then why does this page exist?
Because the question people need answered is who is allowed to test their device, and that answer changes with the address. Give us the address and we will name the credential your tester needs, or point you at your utility's vendor list.
Who sets the rule, the state or my county?
Your water authority, in practice. Virginia's Backflow Prevention Device Worker certification is voluntary by statute, and the statute also forces localities to accept it as proof of training. The program with teeth belongs to the utility, which is why Fairfax, Loudoun and Manassas all read differently.
How often does a device have to be tested?
Annually, in every local program we could find published, plus a test at installation and after a repair. Prince William Water has the owner submit results to its Cross Connection Coordinator. Loudoun Water gives you thirty days from notification to get a failed device repaired or replaced and retested, at your expense.
Does a failed test mean a whole new assembly?
Usually not. Relief valves, check springs and seals are serviceable parts, so most failures are a rebuild with the right kit. Replacing by default is quicker for the contractor and more expensive for you.
My irrigation backflow is dripping now that winter is over. What happened?
Almost always freeze damage. These assemblies sit above grade where the cold gets at them, so water left inside expands and cracks the body or wrecks the internals. Draining the system before the first hard freeze is the whole strategy.
Do I need a permit to install or replace one?
Expect to. USBC Section 108.1 makes work on the water supply and distribution system permit work, and Fairfax County states plainly that installing or replacing a device needs a plumbing permit even like for like, while the annual test does not. Borderline calls belong to your locality, so we confirm.
Why did a plumber tell me I now need an expansion tank?
Because a backflow preventer closes the system. Code Section P2903.4 requires a means of thermal expansion control where such a valve is fitted along with storage water heating. The static pressure ceiling is 80 psi, and over that a pressure-reducing valve is required too.
How do I know whether mine is the testable kind?
Testable assemblies are the ones the state statute names: reduced pressure principle backflow preventors, double check-valve assemblies, double-detector check-valve assemblies and pressure type vacuum breaker assemblies. Non-testable residential dual checks also exist, and Virginia American Water inspects or replaces those on a five-year cycle rather than testing them. Send a photo of the tag and we can usually tell.
I have a letter from the water authority. What is the first move?
Look at who sent it, because that tells you which program you are in. Then call us with the address. We will say whether it wants a test, a repair or an installation, and which of those we can legally do.